Free Delivery for ONLINE PURCHASES over R1500 - Only valid in our 6 Major City Centres
{"id":4837921390672,"title":"NeuroTrac® PelviTone","handle":"neurotrac-pelvitone-1","description":"\u003cdiv id=\"tabs\"\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eAdvanced multi-phase programmes where treatment is split into time phases with different stimulation parameters;\u003c\/li\u003e\n\u003cli\u003eStronger symmetrical stimulation with the reduced Pulse Width : 50 – 330 μS.\u003c\/li\u003e\n\u003cli\u003eThree Custom programmes plus 11 Preset Continence programmes.\u003c\/li\u003e\n\u003cli\u003eLock mode function to measure the home compliance (mA and time used)\u003c\/li\u003e\n\u003cli\u003eNeuroTrac™ VeriProbe – The Vaginal probe for EMG and Electrostimulation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDual channel: individually isolated circuits.\u003c\/li\u003e\n\u003cli\u003eAmplitude: 0-90 mA into 500 Ohm load; actual mA will tend to be less than indicated due to electrode impedance: at 1000 Ohms load (Electrodes in poor condition) the maximum will be limited to 86 mA, at 1500 Ohms load the maximum will be limited to 65 mA.\u003c\/li\u003e\n\u003cli\u003eType: Constant current, maximum output voltage 180 Volts +10 \/ -30 Volts\u003c\/li\u003e\n\u003cli\u003eWaveform: Symmetrical, rectangular bi-phasic with zero DC current.\u003c\/li\u003e\n\u003cli\u003eSelectable pulse width: 50 μS – 330 μS [2% accuracy].\u003c\/li\u003e\n\u003cli\u003ePulse Rate selection: in the continuous mode 2 – 100 Hz [2% accuracy].\u003c\/li\u003e\n\u003cli\u003eTime duration of the treatment selectable: 1 minute to 90 minutes.\u003c\/li\u003e\n\u003cli\u003eLow Battery Indicator: If the battery goes below 6.9 volts +\/- 0.2 volts the battery symbol will flash on\/off once every second.\u003c\/li\u003e\n\u003cli\u003eOpen Electrode Detect: If an open circuit is detected at the output of channel A or B the output current will be reset at zero.\u003c\/li\u003e\n\u003cli\u003eRamp up time 0.1 – 9.9 seconds.\u003c\/li\u003e\n\u003cli\u003eIf the battery voltage is below 6.6 (+\/- 0.2) volts the unit will not turn on.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eNappi Code\u003c\/strong\u003e : 135612-001\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical dimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e134 x 69 x 29.7 mm.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e0.18 KG with battery.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is in the Box:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Neurotrac Tens Unit\u003c\/li\u003e\n\u003cli\u003e1 x Pack of 4 Electrodes\u003c\/li\u003e\n\u003cli\u003e1 x 9V Battery\u003c\/li\u003e\n\u003cli\u003e2 x Leads\u003c\/li\u003e\n\u003cli\u003e1 x User Manual\u003c\/li\u003e\n\u003cli\u003e1 x Carry Bag\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0266\/8563\/files\/Pelvitone_PDF.pdf?v=1596532492\" title=\"Pelvitone\" target=\"_blank\"\u003eRead More\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ch3\u003e Warranty\u003c\/h3\u003e\n\u003cp\u003eAll models carry a warranty of 2 Year from date of purchase. The warranty applies to the simulator only. The warranty does not apply to the leads or electrodes. Warranty does not apply to damage resulting from:\u003c\/p\u003e\n\u003cp\u003e1. Failure to follow the operating manual\u003cbr\u003e2. Accidents\u003cbr\u003e3. Abuse\u003cbr\u003e4. Alteration or \u003cbr\u003e5. Disassembly\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","published_at":"2020-11-14T13:22:19+02:00","created_at":"2020-11-11T17:01:10+02:00","vendor":"Verity Medical","type":"E-Stims for Patients","tags":["Continence Device","Coupon","E-STIMS","Electrical Pain Relief","Electronic Stimulation","Electrotherapy","Muscle Stimulation","Muscle Stimulator for Women","Neurotrac","Neurotrac Pelvitone","NMES","TENS","TENS for Women"],"price":194925,"price_min":194925,"price_max":194925,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":33004247449680,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"ECS200","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"NeuroTrac® PelviTone","public_title":null,"options":["Default Title"],"price":194925,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":"shopify","inventory_policy":"deny","barcode":""}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/0266\/8563\/products\/Neurotrac_Pelvitone_1000_x_1000_d8dce1c5-538f-4cc8-965b-e5a69e79b097.jpg?v=1605106872"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/0266\/8563\/products\/Neurotrac_Pelvitone_1000_x_1000_d8dce1c5-538f-4cc8-965b-e5a69e79b097.jpg?v=1605106872","options":["Title"],"media":[{"alt":null,"id":8958721032272,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1000,"width":1000,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0266\/8563\/products\/Neurotrac_Pelvitone_1000_x_1000_d8dce1c5-538f-4cc8-965b-e5a69e79b097.jpg?v=1605106872"},"aspect_ratio":1.0,"height":1000,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0266\/8563\/products\/Neurotrac_Pelvitone_1000_x_1000_d8dce1c5-538f-4cc8-965b-e5a69e79b097.jpg?v=1605106872","width":1000}],"content":"\u003cdiv id=\"tabs\"\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eAdvanced multi-phase programmes where treatment is split into time phases with different stimulation parameters;\u003c\/li\u003e\n\u003cli\u003eStronger symmetrical stimulation with the reduced Pulse Width : 50 – 330 μS.\u003c\/li\u003e\n\u003cli\u003eThree Custom programmes plus 11 Preset Continence programmes.\u003c\/li\u003e\n\u003cli\u003eLock mode function to measure the home compliance (mA and time used)\u003c\/li\u003e\n\u003cli\u003eNeuroTrac™ VeriProbe – The Vaginal probe for EMG and Electrostimulation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDual channel: individually isolated circuits.\u003c\/li\u003e\n\u003cli\u003eAmplitude: 0-90 mA into 500 Ohm load; actual mA will tend to be less than indicated due to electrode impedance: at 1000 Ohms load (Electrodes in poor condition) the maximum will be limited to 86 mA, at 1500 Ohms load the maximum will be limited to 65 mA.\u003c\/li\u003e\n\u003cli\u003eType: Constant current, maximum output voltage 180 Volts +10 \/ -30 Volts\u003c\/li\u003e\n\u003cli\u003eWaveform: Symmetrical, rectangular bi-phasic with zero DC current.\u003c\/li\u003e\n\u003cli\u003eSelectable pulse width: 50 μS – 330 μS [2% accuracy].\u003c\/li\u003e\n\u003cli\u003ePulse Rate selection: in the continuous mode 2 – 100 Hz [2% accuracy].\u003c\/li\u003e\n\u003cli\u003eTime duration of the treatment selectable: 1 minute to 90 minutes.\u003c\/li\u003e\n\u003cli\u003eLow Battery Indicator: If the battery goes below 6.9 volts +\/- 0.2 volts the battery symbol will flash on\/off once every second.\u003c\/li\u003e\n\u003cli\u003eOpen Electrode Detect: If an open circuit is detected at the output of channel A or B the output current will be reset at zero.\u003c\/li\u003e\n\u003cli\u003eRamp up time 0.1 – 9.9 seconds.\u003c\/li\u003e\n\u003cli\u003eIf the battery voltage is below 6.6 (+\/- 0.2) volts the unit will not turn on.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eNappi Code\u003c\/strong\u003e : 135612-001\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical dimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e134 x 69 x 29.7 mm.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e0.18 KG with battery.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is in the Box:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Neurotrac Tens Unit\u003c\/li\u003e\n\u003cli\u003e1 x Pack of 4 Electrodes\u003c\/li\u003e\n\u003cli\u003e1 x 9V Battery\u003c\/li\u003e\n\u003cli\u003e2 x Leads\u003c\/li\u003e\n\u003cli\u003e1 x User Manual\u003c\/li\u003e\n\u003cli\u003e1 x Carry Bag\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0266\/8563\/files\/Pelvitone_PDF.pdf?v=1596532492\" title=\"Pelvitone\" target=\"_blank\"\u003eRead More\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ch3\u003e Warranty\u003c\/h3\u003e\n\u003cp\u003eAll models carry a warranty of 2 Year from date of purchase. The warranty applies to the simulator only. The warranty does not apply to the leads or electrodes. Warranty does not apply to damage resulting from:\u003c\/p\u003e\n\u003cp\u003e1. Failure to follow the operating manual\u003cbr\u003e2. Accidents\u003cbr\u003e3. Abuse\u003cbr\u003e4. Alteration or \u003cbr\u003e5. Disassembly\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e"}

NeuroTrac® PelviTone

Product Description
Features:
  • Advanced multi-phase programmes where treatment is split into time phases with different stimulation parameters;
  • Stronger symmetrical stimulation with the reduced Pulse Width : 50 – 330 μS.
  • Three Custom programmes plus 11 Preset Continence programmes.
  • Lock mode function to measure the home compliance (mA and time used)
  • NeuroTrac™ VeriProbe – The Vaginal probe for EMG and Electrostimulation.

Technical Data:

  • Dual channel: individually isolated circuits.
  • Amplitude: 0-90 mA into 500 Ohm load; actual mA will tend to be less than indicated due to electrode impedance: at 1000 Ohms load (Electrodes in poor condition) the maximum will be limited to 86 mA, at 1500 Ohms load the maximum will be limited to 65 mA.
  • Type: Constant current, maximum output voltage 180 Volts +10 / -30 Volts
  • Waveform: Symmetrical, rectangular bi-phasic with zero DC current.
  • Selectable pulse width: 50 μS – 330 μS [2% accuracy].
  • Pulse Rate selection: in the continuous mode 2 – 100 Hz [2% accuracy].
  • Time duration of the treatment selectable: 1 minute to 90 minutes.
  • Low Battery Indicator: If the battery goes below 6.9 volts +/- 0.2 volts the battery symbol will flash on/off once every second.
  • Open Electrode Detect: If an open circuit is detected at the output of channel A or B the output current will be reset at zero.
  • Ramp up time 0.1 – 9.9 seconds.
  • If the battery voltage is below 6.6 (+/- 0.2) volts the unit will not turn on.

Nappi Code : 135612-001

Physical dimensions: 

  • 134 x 69 x 29.7 mm.

Weight: 

  • 0.18 KG with battery.

What is in the Box:

  • 1 x Neurotrac Tens Unit
  • 1 x Pack of 4 Electrodes
  • 1 x 9V Battery
  • 2 x Leads
  • 1 x User Manual
  • 1 x Carry Bag

Read More


 Warranty

All models carry a warranty of 2 Year from date of purchase. The warranty applies to the simulator only. The warranty does not apply to the leads or electrodes. Warranty does not apply to damage resulting from:

1. Failure to follow the operating manual
2. Accidents
3. Abuse
4. Alteration or 
5. Disassembly

SKU: ECS200